Sciton ThermaScan™

ThermaScan Overview

Refirme
Pulsed energy at a 1319 nm wavelength allows controlled heating of sub-epidermal layers of the skin. This is ideal for non-invasive wrinkle and acne scar treatment through collagen remodeling or for treating acne by heating sebaceous glands thereby minimizing oil production. The pulse duration and high scattering coefficient limit the heated
region to a uniform thin layer below the epidermal-dermal boundary.

The LAPG (Large Area Pattern Generator) computer-guided high speed scanner provides precise placement of each spot in a non-sequential pattern to prevent excessive heat build-up promoting thermal relaxation time between pulses. In addition, the advanced robotic scanning offers smooth operation, faster treatments, and 100% coverage.

To achieve optimal safety and patient comfort, the LAPG provides integrated contact cooling through sapphire plates and a powerful external chilling unit. The intelligent user interface provides user-friendly and quick guidance to initial settings for the treating conditions. ThermaScan is designed for all skin types including tanned skin. For more information …

Clinical Applications

The infrared laser treatment requires heating the target region to an elevated temperature within a narrow temperature band.

Rejuvenation of dermal collagen includes:

  • Wrinkles
  • Acne
  • Acne scars
  • Skin tone and texture

Science + Technology

Collagen Remodeling

Non-ablative techniques are motivated by the idea that collagen remodeling happens with an intact epidermal layer.

  • Thermally injure a dermal region in the skin
  • Initiate the body’s wound healing response
  • Stimulate fibroblast activity
  • Exercise the skin’s wound healing ability to remodel or replace collagen

Large Area Pattern Generator (LAPG™) & Non-Sequential Scanning

  • ThermaScan utilizes the LAPG high speed scanner with continuous contact cooling for precise, uniform coverage
  • The computer guided scanner covers large areas rapidly and evenly
  • Maximizes the time interval between adjacent spots
  • Minimizes subsurface heat buildup
  • High speed, uniform coverage
  • Improves efficacy

Powerful Cooling

ThermaScan’s powerful sapphire plate contact cooling, for pre-, during, and post-treatment, provides increased patient safety and comfort.

Beam Profile

The precise targeted flat-top beam profile causes less energy scattering and enables deep penetration to targeted chromophores. Uniform energy distribution results in even treatment to prevent central heat buildup

PhotoTherapy

ClearScan YAG™

ClearScan YAG Overview

Refirme
ClearScan YAG’s 1064 nm Nd:YAG wavelength and pulse duration are unmatched for permanent hair reduction and vascular lesions from telangiectasias to reticular leg and facial veins.

The selective 1064 nm wavelength has strong absorption in oxyhemoglobin and melanin, resulting in selective heating of veins and hair follicles, which produces excellent clinical results. The powerful contact cooling enables treatments to be safe for all skin types and tanned skin.

ClearScan YAG’s large area pattern generator (LAPG), fast speed, non-sequential scanning, powerful cooling, and flat-top beam profile provide optimal results and patient comfort during the procedure.

Clinical Applications

ClearScan YAG is FDA cleared for permanent hair reduction and treating vein and vascular conditions:

Permanent Hair Reduction – Removal of unwanted hair or permanent hair reduction through selective targeting of melanin in hair follicles, and for the treatment of pseudofolliculitis barbae (PFB).

Vein and Vascular – Benign vascular lesions, port wine stains, hemangiomas, warts, telangiectasia, rosacea, venous lake, leg veins and spider veins.

Science + Technology

Large Area Pattern Generator (LAPG™) & Non-Sequential Scanning

  • ClearScan YAG utilizes the LAPG high speed scanner in a non-sequential delivery for comfortable hair reduction with continuous contact cooling for precise, uniform coverage.
  • The computer guided scanner covers large areas rapidly and evenly.
  • Maximizes the time interval between adjacent spots for precision thermal relaxation time.
  • Minimizes subsurface heat build-up providing additional comfort during treatment.
  • High speed, uniform coverage.
  • Improved efficacy.

Powerful Cooling

ClearScan YAG’s powerful sapphire plate contact cooling, for pre-, during, and post-treatment, provides increased patient safety and comfort.

Product Highlights

Fast treatment. ClearScan YAG can cover large areas 4x faster than other systems, with only 200 scans to cover a large back. Most systems require thousands of hand-placed spots to cover the same area.

Powerful Contact Cooling

A 250-watt integrated contact cooling device controls skin temperature at any treatment speed. It is the first system to use non-selective bulk cooling for comfort and safety.

Sciton Laser SkinTyte

Joule

SkinTyte Overview

Available on the JOULE platform system or a standalone BBLs, SkinTyte delivers uniform, targeted and deep heating to effectively coagulate soft tissue in stimulating collagen contraction and re-modeling. Since there is no downtime, patients may resume their regular activities immediately following treatment.

Safe for all skin types, SkinTyte can predictably and effectively treat any area of the body where improvement is desired, giving patients a firmer, more youthful appearance. SkinTyte utilizes infrared energy to deeply heat soft tissue while protecting the entire treated area with sapphire contact cooling. This heating process causes soft tissue coagulation that tightens tissue and initiates the body’s natural healing process. Following treatment, a new foundation of collagen is created leading to increased skin
firmness.

Clinical Applications

Safe for all skin types, SkinTyte can predictably and effectively treat any area of the body where improvement is desired, giving patients a firmer, more youthful appearance. SkinTyte utilizes infrared energy to deeply heat soft tissue while protecting the entire treated area with sapphire contact cooling. This heating process causes soft tissue coagulation that tightens tissue and initiates the body’s natural healing process. Following treatment, a new foundation of collagen is created leading to increased skin firmness.

Science + Technology

SkinTyte utilizes advanced infrared light technology to deeply heat dermal collagen while continuously protecting the treated epidermis with sapphire contact cooling for maximum safety and comfort. With no need for a topical anesthetic, the energy is delivered in rapid, gentle pulses to promote contraction and partial coagulation of the collagen, initiating the body’s natural healing process. Following treatment, a new foundation of collagen is created leading to increased skin firmness.

SkinTyte’s large 15 x 45 mm spot size and rapid repetition rate allows you to treat more patients in less time. Physicians can also quickly treat small areas with ease with the magnetic Finesse Adapters, available in three convenient sizes, 15 x 15 mm square and 11 mm and 7 mm round.

The integrated thermoelectric monitoring assembly enables its sapphire crystal and sensors to continually and precisely maintain temperatures from 0°C – 30°C with adjustabilit of every degree in between. Patients will be comfortable throughout treatment.

SkinTyte not only offers superior value, but the durable design means no consumables for your practice. The uniquely designed dual-lamp technology greatly extends lamp life, offering unlimited pulses under warranty.

Skin Firming